TwinCAT Usermode Runtime System Test
Full chain on Usermode Runtime (not the real-time IPC target unless the user says so).
Quick Start
Prefer one call when available:
twincat_umrt_e2e(sln_path="<path.sln>", xae_version="4026", confirm=true)
Or walk steps manually:
Task Progress:
- [ ] 0. Prerequisites / ask user (licenses) if unknown
- [ ] 1. UmRT status + start (window_mode=hidden)
- [ ] 2. twincat_open (.sln, xae_version=4026 if Build 4026) — check pin_honored
- [ ] 3. twincat_io_set_disabled(all_devices=true)
- [ ] 4. twincat_set_target(UmRT NetId)
- [ ] 5. twincat_activate → twincat_start — require activate_ok / boot_ok
- [ ] 6. twincat_runtime_messages(since_last_activate=true)
- [ ] 7. twincat_runtime_state — require ready_for_ads (plc_start if needed)
- [ ] 8. twincat_ads_symbols + twincat_ads_read_list + write smoke
- [ ] 9. Report PASS/FAIL checklist
Discover tools via GetMcpTools on one server
(user-mcp-twincat-local for local MCP dev, else
plugin-twincat-ai-toolkit-mcp-twincat). Do not call both in one turn.
Optional CLI helper (same steps, no agent):
python mcp-servers/mcp-twincat/systemtest/umrt_chain.py --sln "<path.sln>" --xae-version 4026
Prerequisites
| Need | Notes |
|---|---|
| TwinCAT 4026 + TC170x UmRT | Engineering on 4024/4022 with UmRT is unsupported |
| 7-day trial / runtime licenses on UmRT | Manual in XAE (SYSTEM→License). AI cannot enter the security code. Ask in Step 0 if unknown. Blocking user_action_required appears only when licenses_ok=false / license findings — not on every UmRT start |
Sample or app .sln |
Prefer full path to .sln |
Read also: rules/twincat3-mcp-runtime.mdc.
Library export during online-test (time saver)
If the live diagnose needs a fresh library export/install before activate,
export only .library — skip .compiled-library to save time:
twincat_export_library(library=true, compiled_library=false, wait=false, timeout_seconds=1800)
# poll twincat_export_progress until running=false
This shortcut applies only to /twincat3-cmd-online-test / this skill.
For /twincat3-cmd-new-version, /twincat3-cmd-release, or any library update,
always export both .library and .compiled-library (skills
twincat3-new-version / twincat3-release, rule twincat3-mcp-build).
Timing on UmRT (TON / TOF / TIME) — by design
InfoSys TC170x Limitations (tc170x_tc3_usermode_runtime/1033/11319889035.html, DE: …/1031/… Limitierungen):
- No guaranteed deterministic execution; Windows may interrupt UmRT at any time.
- Min. task base time 1 ms; execution times / jitter can affect function.
- Some functions need a constant real-time tick (unlike IPC RT).
→ Timers (TON, TOF, TIME, cycle waits) often appear slower or less precise in wall-clock time than on a real-time target. This is intentional UmRT behaviour.
In verification: wait longer / poll Q/bDone via ADS; do not FAIL only because elapsed wall time exceeds the configured PT compared to IPC.
Step 0 — Ask user if licenses unknown
If UmRT was never licensed on this PC/instance, ask:
Please activate 7-day trial licenses on the UmRT target (SYSTEM→License → 7 Days Trial License) for TC3 PLC and any TF* used. Confirm when done.
Do not spin activate/start retries on license errors.
Step 1 — Usermode Runtime
twincat_umrt_status()
twincat_umrt_start(confirm=true, window_mode="hidden")
- Record
ams_net_id/ instance name from the response. - Prefer
window_mode="hidden"for MCP (no console). Run mode via COM/twincat_start, not keyr. - I/O may appear as non-blocking prerequisite. Ask user only when
ask_user=true(e.g. real license failure later, or non-UmRT target).
Step 2 — Open solution
twincat_open(path="<sln>", xae_version="4026")
Prefer .sln. Check success, pin_honored, attached_xae_version,
created_new_instance, plc_project_name.
Step 3 — Disable physical I/O
UmRT has no EtherCAT; active I/O → SAFEOP / AdsError 1823.
twincat_io_list()
twincat_io_set_disabled(all_devices=true, disabled=true, confirm=true)
Step 4 — Target = UmRT
twincat_set_target(net_id="<umrt ams_net_id>", confirm=true)
twincat_get_target() # must match UmRT
Do not leave the Beckhoff IPC (e.g. C6015) as target unless the user explicitly wants that.
Step 5 — Activate + Start
twincat_activate(confirm=true)
twincat_start(confirm=true)
Require activate_ok / boot_ok (and status=success). Do not parse
Output-log tails (“erfolgreich”). Inspect runtime_findings /
has_blocking_runtime_error / licenses_ok.
Step 6 — Runtime messages / diagnose
twincat_runtime_messages(since_last_activate=true)
| Finding id | Action |
|---|---|
license |
Ask user for trial licenses; stop (licenses_ok=false) |
page_fault / fatal / exception |
FAIL — report matched lines; do not continue ADS |
safeop_aborted |
Ensure I/O disabled; re-activate; if persists, FAIL |
| none | Continue |
Also useful: twincat_status for dialogs / prereqs / sys_manager_errors.
Step 7 — System + PLC ADS state
twincat_runtime_state() # expect ready_for_ads=true
twincat_plc_start(confirm=true, port=851) # if ready_for_ads false / PLC not RUN
twincat_runtime_state()
ready_for_ads requires system and PLC AdsState RUN. System RUN alone is
not enough. After activate, PLC port 851 may stay INVALID until
twincat_plc_start.
Step 8 — ADS symbols + R/W verify
twincat_ads_symbols(prefix="<PROG>.", max_symbols=50)
Pick concrete scalar paths (BOOL/INT/UINT/REAL). Avoid whole-FB/ENUM reads without type (pyads NoneType).
Batch read (preferred for many vars):
twincat_ads_read_list(symbols='["PROG.fbX._bFlag", "PROG.stControl.bOn"]')
Write smoke + verify (use a non-critical private/config scalar if possible):
twincat_ads_read(symbol="…")
twincat_ads_write(symbol="…", value="…", confirm=true)
twincat_ads_read(symbol="…") # expect new value (or document cyclic overwrite)
Or batch:
twincat_ads_write_list(values='{"path": value}', confirm=true)
twincat_ads_read_list(symbols='["path"]')
Path rules (short)
- Full instance path; nested/private
_OK even if missing fromtwincat_ads_symbols {attribute 'hide'}on entire FB type: members still R/W via derived instance path{attribute 'hide'}on single var/PROPERTY/VAR_STAT: not found (1808)
Step 9 — Report
Return a compact checklist:
UmRT systemtest
- UmRT start: PASS/FAIL (net_id=…, window=hidden)
- Open solution: PASS/FAIL
- I/O disabled: PASS/FAIL
- Target UmRT: PASS/FAIL
- Activate/Start: PASS/FAIL
- Runtime msgs: PASS/FAIL (findings=…)
- Sys RUN: PASS/FAIL
- PLC RUN: PASS/FAIL
- ADS read_list: PASS/FAIL (n=…)
- ADS write: PASS/FAIL (path=…, note=cyclic overwrite?)
Overall PASS only if all required steps PASS (write may PASS with note if PLC overwrites within 1 cycle but t+0 read showed the write).
Fail-fast
- License / page_fault / fatal → stop, ask user or report; no ADS spam
- Missing UmRT install → tell user to install TC170x workload
- Do not switch back to IPC target unless asked
- Do not
twincat_closeunless user asks or XAE is stuck - If any activate/start/plc_*/set_runtime_mode result has
target_is_mcp_umrt: false/non_umrt_target_control→ stop, tell the user you would control a real/external target, and only continue if they explicitly want that (not a silent UmRT test) - Timer/TON wall-clock slower than on IPC → not a fail (UmRT Limitations)
Related
- Rule:
twincat3-mcp-runtime - Command:
/twincat3-cmd-online-test - After
ready_for_ads: interactive ADS / timed Python →/twincat3-cmd-live-diagnostics(skilltwincat3-live-diagnostics) - Helper:
mcp-servers/mcp-twincat/systemtest/umrt_chain.py